FiberOptic Kft.

I-F(ZN)H & I-F(ZN)HH Multifiber Trunks

  • Application: Indoor
  • Mode: G50/125 OM3, G50/125 OM4, E09/125 G.657.A1
  • Termination: MPO, MTP
  • Fibers: 12, 24, 48, 96, 144, 72

CABLING PROPERTIES

Standardization

IEC 60794-2

Construction

I-FN(ZN)H or I-FN(ZN)HH cable incl. Ø3.0mm 12 fiber sub-units

Buffer type

N/A

Strength member

Non-metallic aramid yarns

Jacket material

FRNC (TPE-0), LSZH/LS0H

Jacket dimensions [mm]

3.0 (1x12) 8.9 (up to 4x12), 13.1 (8x12), 16.5 (12x12)

Min. bend radius (static) [mm]

130 (up to 4x12), 250 (up 12x12),  (acc. to IEC 60794-1-21 E11)

Min. bend radius (dynamic) [mm]

200 (up to 4x12), 330 (up 12x12) (acc. to IEC 60794-1-21 E11)

Applicable tensile load (long term) [N]

800 (up to 4x12), 1000 (up 12x12) (acc. to IEC 60794-1-21 E1)

Crush resistance (long term) [N/dm]

1000

 

FIRE BEHAVIOUR

Fire load [MJ/m]

0.14

Temperature range (operation) [°C]

-5 to +60 (acc. to IEC 60794-1-22 F1)

Flame retardancy

IEC 60332-1-2, IEC-60332-3-22 Cat.A

Smoke density

IEC 61034

Absence of halogen

IEC 60754-1

Acidity of combustion gases

IEC 60754-2

 

CODING & TERMINATION

Colour coding of cable jacket

OM3: aqua, OM4: heather violet, SM: yellow

Colour coding of connectors and boots

OM3/PC: aq, OM4/PC: h.violet, SM/UPC: bl, SM/APC8°: gn

Polarity

A, B or C

Available connectors

MPO, MTP

Max. applicable connector load [N]

100N

Max. mating cycles

500

 

OPTICAL PERFORMANCE

Endface geometry

100% acc. to IEC 61755-3-1/2

Instertion loss (acc to. IEC 61753) [dB]

0.15 typ, 0.30dB max (100% testing acc. to IEC 61300-3-4 Method B

Return loss (MM PC) [dB]

-35.0 max (100% testing acc. to IEC 61300-3-6)

Return loss (SM UPC) [dB]

-55.0 max (100% testing acc. to IEC 61300-3-6)

Return loss (SM APC8°) [dB]

-65.0 max (100% testing acc. to IEC 61300-3-6)