FiberOptic Kft.

I-V Pigtails & Pigtail Sets

  • Application: Indoor
  • Mode: G50/125 OM3, G50/125 OM4, E09/125 G.652.D, E09/125 G.657.A1
  • Termination: DIN (LSA), E2000 (LSH), FC, LC, MU, SC, ST
  • Fibers: 1, 12

CABLING PROPERTIES

Standardization

IEC 60794-2

Construction

I-V buffered fiber 1xØ0.9mm or in bundle of 12xØ0.9mm set

Buffer type

STB900U (semi-tight buffer, unfilled/dry)

Jacket material

FRNC (TPE-0), LSZH/LS0H

Jacket dimensions [mm]

Ø0.9

Min. bend radius (static) [mm]

30 (acc. to IEC 60794-1-21 E11)

Min. bend radius (dynamic) [mm]

30 (acc. to IEC 60794-1-21 E11

Applicable tensile load (long term) [N]

5 (acc. to IEC 60794-1-21 E1)

Crush resistance (long term) [N/dm]

200 (acc. to IEC 60794-1-21 E3)

 

FIRE BEHAVIOUR

Temperature range (operation) [°C]

-5 to +60 (acc. to IEC 60794-1-22 F1)

Flame retardancy

IEC 60332-1-2, IEC-60332-3-22 Cat.A

Smoke density

IEC 61034

Absence of halogen

IEC 60754-1

Acidity of combustion gases

IEC 60754-2

 

CODING & TERMINATION

Colour coding of cable jacket

OM3: aqua, OM4: heather violet, SM: yellow

Colour coding of connectors and boots

OMX/PC: acc. to jacket colour, SM/UPC: blue, SM/APC8°: green

Available connectors

LSA (DIN), E2000 (LSH), FC, LC, MU, SC, ST

Max. applicable connector load [N]

5N

Max. mating cycles

500

 

OPTICAL PERFORMANCE

Endface geometry

100% acc. to IEC 61755-3-1/2

Instertion loss (acc to. IEC 61753) [dB]

0.15 typ, 0.30dB max (100% testing acc. to IEC 61300-3-4 Method B

Return loss (MM PC) [dB]

-35.0 max (100% testing acc. to IEC 61300-3-6)

Return loss (SM UPC) [dB]

-55.0 max (100% testing acc. to IEC 61300-3-6)

Return loss (SM APC8°) [dB]

-65.0 max (100% testing acc. to IEC 61300-3-6)