CABLING PROPERTIES |
|
Standardization |
IEC 60794-2 |
Construction |
AT-V(ZN)H(ZN)Y with 2xØ1.8mm units |
Buffer type |
TB900U (tight buffer, unfilled/dry) |
Jacket material |
PVC, LSZH/LS0H |
Strength member |
Non-metallic aramid yarns, two extra strength members |
Jacket dimensions [mm] |
6.8 |
Min. bend radius (static) [mm] |
70 (acc. to IEC 60794-1-21 E11) |
Min. bend radius (dynamic) [mm] |
140 (acc. to IEC 60794-1-21 E11) |
Applicable tensile load (long term) [N] |
200 (acc. to IEC 60794-1-21 E1) |
Crush resistance (long term) [N/dm] |
500 (up to 12x0.9), 1500 (24x0.9) (acc. to IEC 60794-1-21 E3) |
FIRE BEHAVIOUR |
|
Fire load [MJ/m] |
0.86 |
Temperature range (operation) [°C] |
-20 to +90 (acc. to IEC 60794-1-22 F1) |
Flame retardancy |
IEC 60332-1-2, IEC-60332-3-22 Cat.A |
Smoke density |
IEC 61034 |
Absence of halogen |
IEC 60754-1 |
Acidity of combustion gases |
IEC 60754-2 |
CODING & TERMINATION |
|
Colour coding of cable jacket |
Black |
Colour coding of Ø0.9mm units |
IEC 60304 |
Colour coding of connectors and boots |
Black |
Available connectors |
PDLC |
Max. applicable connector load [N] |
100N |
Max. mating cycles |
500 |
OPTICAL PERFORMANCE |
|
Endface geometry |
100% acc. to IEC 61755-3-1/2 |
Instertion loss (acc to. IEC 61753) [dB] |
0.15 typ, 0.30dB max (100% testing acc. to IEC 61300-3-4 Method B |
Return loss (MM PC) [dB] |
-35.0 max (100% testing acc. to IEC 61300-3-6) |
Return loss (SM UPC) [dB] |
-55.0 max (100% testing acc. to IEC 61300-3-6) |
Return loss (SM APC8°) [dB] |
-65.0 max (100% testing acc. to IEC 61300-3-6) |