CABLING PROPERTIES |
|
Standardization |
IEC 60794-2 |
Construction |
I-V(ZN)H jacketed Simplex Ø1.8/2.8mm or Duplex 2xØ1.8/2.8mm |
Buffer type |
TB900U (tight buffer, unfilled/dry) |
Strength member |
Non-metallic aramid yarns |
Jacket material |
FRNC (TPE-0), LSZH/LS0H |
Jacket dimensions [mm] |
Simplex: 1.8, 2.8 or Duplex: 1.8x3.7, 2.8x5.7 |
Min. bend radius (static) [mm] |
30 (acc. to IEC 60794-1-21 E11) |
Min. bend radius (dynamic) [mm] |
60 (acc. to IEC 60794-1-21 E11 |
Applicable tensile load (long term) [N] |
400 (acc. to IEC 60794-1-21 E1) |
Crush resistance (long term) [N/dm] |
100 (Simplex 1.8), 150 (Simplex 2.8), 200 (Duplex 1.8), 400 (Duplex 2.8) (acc. to IEC 60794-1-21 E3) |
FIRE BEHAVIOUR |
|
Fire load [MJ/m] |
0.10 (SX1.8), 0.18 (SX2.8), 0.20 (DX1.8), 0.36 (DX2.8) |
Temperature range (operation) [°C] |
-5 to +60 (acc. to IEC 60794-1-22 F1) |
Flame retardancy |
IEC 60332-1-2, IEC-60332-3-22 Cat.A |
Smoke density |
IEC 61034 |
Absence of halogen |
IEC 60754-1 |
Acidity of combustion gases |
IEC 60754-2 |
CODING & TERMINATION |
|
Colour coding of cable jacket |
OM1: gr, OM2: or, OM3: aq, OM4: heather vi, OM5: lime, SM: ye |
Colour coding of connectors and boots |
OMX/PC: acc. to jacket colour, SM/UPC: blue, SM/APC8°: green |
Polarity (Duplex only) |
Crossover (A-to-B), Straight (A-to-A) on request |
Available connectors |
LSA (DIN), E2000 (LSH), FC, LC, MU, MTRJ (DX1.8 only) SC, ST |
Max. applicable connector load [N] |
100N |
Max. mating cycles |
500 |
OPTICAL PERFORMANCE |
|
Endface geometry |
100% acc. to IEC 61755-3-1/2 |
Instertion loss (acc to. IEC 61753) [dB] |
0.15 typ, 0.30dB max (100% testing acc. to IEC 61300-3-4 Method B |
Return loss (MM PC) [dB] |
-35.0 max (100% testing acc. to IEC 61300-3-6) |
Return loss (SM UPC) [dB] |
-55.0 max (100% testing acc. to IEC 61300-3-6) |
Return loss (SM APC8°) [dB] |
-65.0 max (100% testing acc. to IEC 61300-3-6) |